{"id":261,"date":"2026-03-23T10:57:32","date_gmt":"2026-03-23T02:57:32","guid":{"rendered":"https:\/\/www.envsin-testchamber.com\/?post_type=product&#038;p=261"},"modified":"2026-05-22T10:14:33","modified_gmt":"2026-05-22T02:14:33","slug":"high-and-low-temperature-humidity-low-air-pressure-test-chamber","status":"publish","type":"product","link":"https:\/\/www.envsin-testchamber.com\/pl\/product\/high-and-low-temperature-humidity-low-air-pressure-test-chamber\/","title":{"rendered":"Wysoka i niska temperatura Wilgotno\u015b\u0107 Niskie ci\u015bnienie powietrza Komora testowa"},"content":{"rendered":"<p><span style=\"font-family: arial, helvetica, sans-serif;\">A high\/low temperature and low pressure test chamber is a device specifically designed to simulate the performance of materials, components, or products in high-altitude environments. This chamber can operate under varying temperature and low pressure conditions, helping researchers and developers understand the reliability and durability of products in high-altitude, low-pressure, and extreme temperature environments.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">This test chamber is suitable for simulating environmental tests on complete devices, components, and materials under single or multiple climate factors (high temperature, low temperature, damp heat, low pressure). It is used to evaluate the reliability of products or material components under corresponding temperature, damp heat, and low pressure environments for use, storage, and transportation. It can also simultaneously test the electrical performance parameters of the test specimens while they are powered on.<\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Parametry produktu<\/strong><\/span><\/p>\n<table style=\"width: 100%; border-collapse: collapse; border: 1px solid #000; font-family: Arial, sans-serif; font-size: 14px;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #000; padding: 8px; text-align: left; background-color: #f0f0f0; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Parametr<\/span><\/th>\n<th style=\"border: 1px solid #000; padding: 8px; text-align: left; background-color: #f0f0f0; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">ETQ7025<\/span><\/th>\n<th style=\"border: 1px solid #000; padding: 8px; text-align: left; background-color: #f0f0f0; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">ETQ7050<\/span><\/th>\n<th style=\"border: 1px solid #000; padding: 8px; text-align: left; background-color: #f0f0f0; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">ETQ7100<\/span><\/th>\n<th style=\"border: 1px solid #000; padding: 8px; text-align: left; background-color: #f0f0f0; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">ETQ7200<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Obj\u0119to\u015b\u0107 testowa<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">250 Liters<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">500 litr\u00f3w<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">1000 Liters<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">2000 Liters<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Chamber Dimensions<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">(W\u00d7D\u00d7H)<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">600mm \u00d7 600mm \u00d7<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">700mm<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">800mm \u00d7 700mm \u00d7<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">900mm<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">1000mm \u00d7 1000mm \u00d7<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">1000mm<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">1400mm \u00d7 1200mm \u00d7<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">1200mm<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Wymiary ca\u0142kowite<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">(W\u00d7D\u00d7H)<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">1000mm \u00d7 1800mm \u00d7<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">1880mm<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">1500mm \u00d7 2750mm \u00d7<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">1900mm<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">1400mm \u00d7 3250mm \u00d7<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">2000mm<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">1810mm \u00d7 3710mm \u00d7<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">2310mm<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Zasilanie<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\" colspan=\"4\"><span style=\"font-family: arial, helvetica, sans-serif;\">AC380V \u00b110%, 50Hz \u00b11, 3-fazowy 4-przewodowy + uziemienie (3\/N\/PE), rezystancja uziemienia &lt;4\u03a9<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Maks. Moc systemu<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Approx. 29.4 kW<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Approx. 39.4 kW<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Approx. 54.7 kW<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Approx. 60.7 kW<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Maks. Pr\u0105d systemu<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Approx. 47.2 A<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Approx. 77.2 A<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Approx. 95 A<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Approx. 102.5 A<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Metoda ch\u0142odzenia<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\" colspan=\"4\"><span style=\"font-family: arial, helvetica, sans-serif;\">Typ ch\u0142odzony wod\u0105 (agregat ch\u0142odniczy)<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Installation Site<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">Requirements<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\" colspan=\"4\"><span style=\"font-family: arial, helvetica, sans-serif;\">1. Level floor, good ventilation, free from flammable, explosive, or corrosive gases\/dust.<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">2. Drainage facility within 2m of the refrigeration unit for condensate removal.<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">3. Floor load capacity \u2265 60 kg\/m\u00b2.<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">4. Power supply compliant with chamber requirements.<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">5. If water or air supply is required, pre-install connections.<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">6. Ambient temperature: 5\u00b0C~25\u00b0C for optimal performance; 25\u00b0C~35\u00b0C for normal operation (air-cooled type); 5\u00b0C~40\u00b0C for normal operation (water-cooled type with appropriate cooling water system).<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">7. Ambient humidity: \u226485% RH.<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">8. Atmospheric pressure: 86kPa~106kPa.<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">9. Sufficient clearance for maintenance around the unit.<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Cooling Water Source<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\" colspan=\"4\"><span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Water temperature:<\/strong> 5\u00b0C ~ 28\u00b0C ensures full performance; 28\u00b0C ~ 33\u00b0C permissible (cool-down rate may vary). If using air-conditioning water \u226410\u2103, take measures against condensation.<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\"><strong>If air-cooled version is selected:<\/strong> no cooling water required.<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\"><strong>If a new cooling water circulation system is needed:<\/strong> cooling tower capacity \u226550 tons or chiller cooling capacity \u226560 kW (at 20\u2103); the system shall comply with GB50050-1995 &#8220;Standard for Design of Industrial Circulating Cooling Water Treatment&#8221;.<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top; font-weight: bold;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Test temperatury<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">Parameters<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\"><span style=\"font-family: arial, helvetica, sans-serif;\">Inlet water: \u226538 tons\/hour<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">Pipe diameter: G2.5 inch \u00d7 2<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">Inlet pressure: 0.3MPa ~ 0.6MPa<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">Pressure difference (inlet-outlet):\u22650.2MPa<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\">Water quality: complies with GB50050-1995<\/span><\/td>\n<td style=\"border: 1px solid #000; padding: 8px; vertical-align: top;\" colspan=\"3\"><span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Zakres temperatur:<\/strong> -72\u00b0C ~ +180\u00b0C<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\"><strong>R\u00f3wnomierno\u015b\u0107 temperatury:<\/strong> \u00b12.0\u00b0C<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Wahania temperatury:<\/strong> \u00b10.5\u00b0C<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Szybko\u015b\u0107 ogrzewania:<\/strong> \u226510\u2103\/min point-to-point linear (ambient pressure, -65\u2103~+125\u2103)<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Szybko\u015b\u0107 ch\u0142odzenia:<\/strong> \u226510\u2103\/min point-to-point linear (ambient pressure, -65\u2103~+125\u2103)<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Humidity range:<\/strong> 10%RH ~ 98%RH<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Humidity uniformity:<\/strong> \u00b13,0%RH<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Humidity deviation:<\/strong> \u00b13,0%RH<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Pressure control range:<\/strong> ambient pressure ~ 5kPa, adjustable; low temp capability (-55\u2103, 2.7kPa)<\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Pressure reduction time:<\/strong> &lt;45 min (ambient pressure \u2192 0.5kPa)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Cechy produktu<\/strong><\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">1. Expandable mobile platform management via APP<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">2. Specially designed water-ring low-pressure control technology for efficient and balanced pressure control.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">3. Multiple protection facilities, equipped with a wireless remote alarm device.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">4. Uses an LCD touch screen with a fault dialogue menu and a fault diagram and troubleshooting menu.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">5. Built-in radiation shield design effectively ensures temperature uniformity under low pressure conditions.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">6. Inteligentna i wydajna technologia sterowania przep\u0142ywem ch\u0142odzenia serwo, oszcz\u0119dno\u015b\u0107 energii oraz szybki i precyzyjny wzrost i spadek temperatury.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">7. The equipment can be expanded with remote service functions and provides machine training CDs.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">8. The test program has intelligent power-off reset, automatic memory link, and automatic origin start functions.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\"><strong>Aplikacje i scenariusze<\/strong><\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">1. Lotnictwo i kosmonautyka:<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Aircraft component testing: Evaluates the performance of aircraft components (such as electronic equipment, structural materials, seals, etc.) under high-altitude, low-temperature, and low-pressure conditions to ensure their reliability and safety during high-altitude flight.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Spacecraft equipment testing: Tests the durability and stability of spacecraft components (such as satellite electronic equipment, solar panels, etc.) in the space environment to ensure their normal operation in orbit.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">2. Electronics and electrical industry:<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Electronic component testing: Evaluates the performance and reliability of electronic components (such as semiconductor chips, capacitors, resistors, etc.) under extreme temperature and low-pressure environments. Consumer Electronics Testing: Tests the stability of consumer electronics products such as smartphones, laptops, and tablets under high and low temperature and low pressure conditions to ensure their normal operation in high-altitude areas.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">3. Automotive Industry:<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Automotive Electronics: Evaluates the performance of in-vehicle electronic equipment (such as navigation systems, sensors, and control units) in high-altitude and low-temperature environments to ensure their reliability under various geographical conditions.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Engine Testing: Tests the starting performance and operational stability of engines and related components under low pressure and low temperature conditions to ensure the normal operation of vehicles in high-altitude areas.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">4. Military Equipment:<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Military Electronic Equipment: Evaluates the performance and reliability of military electronic equipment (such as communication equipment, navigation devices, and radar) under extreme environmental conditions to ensure their normal operation in various combat environments.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Personal Equipment: Tests the durability of portable equipment used by soldiers (such as night vision devices, flashlights, and communication equipment) in high-altitude and low-temperature environments.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">5. Farmaceutyki i biotechnologia:<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Pharmaceutical Stability Testing: Evaluates the stability and efficacy of pharmaceuticals under extreme temperature and low pressure environments to ensure their quality under different storage and transportation conditions.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Biological Product Testing: Testing the stability and activity of vaccines and other biological products under low temperature and low pressure conditions to ensure their effectiveness in high-altitude areas.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">6. Materials Science:<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Materials Durability Testing: Evaluating the physical and chemical properties of novel materials (such as high-performance composite materials and coating materials) under extreme temperature and low pressure environments.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Sealing Material Testing: Testing the sealing performance of various sealing materials under low pressure and extreme temperature conditions to ensure their reliability in practical applications.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">7. Telecommunications Industry:<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Communication Equipment Testing: Evaluating the performance of base stations, antennas, satellite communication equipment, etc., under high altitude and extreme temperature conditions to ensure their stable operation in harsh environments.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif;\">Fiber Optic and Connector Testing: Testing the connection performance and durability of fiber optics and connectors under low pressure and extreme temperature conditions.<\/span><\/p>","protected":false},"author":1,"featured_media":796,"template":"","meta":{"_acf_changed":false},"product_category":[8],"class_list":["post-261","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-weather-resistance-test-series"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.envsin-testchamber.com\/pl\/wp-json\/wp\/v2\/product\/261","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.envsin-testchamber.com\/pl\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.envsin-testchamber.com\/pl\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/www.envsin-testchamber.com\/pl\/wp-json\/wp\/v2\/users\/1"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.envsin-testchamber.com\/pl\/wp-json\/wp\/v2\/media\/796"}],"wp:attachment":[{"href":"https:\/\/www.envsin-testchamber.com\/pl\/wp-json\/wp\/v2\/media?parent=261"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"https:\/\/www.envsin-testchamber.com\/pl\/wp-json\/wp\/v2\/product_category?post=261"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}